Customization: | Available |
---|---|
Function Type: | Mixing System, Infrared Range and Communication System, Search and Tracking System |
Detection Type: | Si or Ingaas |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
1) Forging; steel rolling; titanium alloy; pipe welding;
2) Heat treatment; refractory materials
; tungsten and molybdenum materials;
chemical industry
;
3) vacuum equipment;
scientific research experiment
;
Features:
1) Easy Installation: fixing on the machine, aiming at the object, directly measure the temperature during the thermal process.
2) Accurate measurement: Ratiometric make sure overcome the influence of dust, smoke, water vapour, a small amount of steel slag and other factors, accurately measure the temperature of object.
Especially, during metal thermal process, quickly oxidized on the metal surface to form an oxide layer, the layer shed or crack with the change of temperature. The gap between the oxide skin and the metal body formed, making the temperature of the oxide layer lower than the metal body.
Through special wavelength selection and software algorithm processing, the ratiometric thermometer can overcome the error caused, get reliable data for process analysis.
It also has advantages for vacuum or protective gas heating systems, which can overcome the measurement error caused by glass window materials and make the measured value closer to the true value.
3) Little maintenance: protected in a strong stainless steel case to resist harsh working environment, durable.
4) Convenient management: special software for thermal field, centralized data management in different factories and production lines. Palm management, and multi-terminal visualization. Customized accepted based on user requirements, quality check, inspection, statistics and other functions.
Working Method:
Item | Description | |
1 |
Visual targeting system
|
--check it aligned to the target or not; --If sealed environment, visual aiming also be used as a window to observe the working status; --no limitation for measuring distances |
2 | analog output | 0-5V/0-20mA/4-20mA |
3 | Digital output | RS485(optional) |
4 | Working method | Single color/ two color (alternative) |
Item | Parameter | |
1 | Measurement range | 400-1400ºC/600-1600ºC/ 800-2500ºC/ 1000-3000ºC |
2 | Spectral range | 0.8-1.1µm and 0.4-1.1µm |
3 | Distance-to-Spot Ratio (D:S) | 280:1 |
4 | Accuracy | ±0.75%(FS) |
5 | Repeatability | 0.2% |
6 | Response time(95%) | ≤5ms |
7 | Temperature resolution(analog) | 0.5ºC |
8 | Temperature resolution(digital) | 0.1ºC |
9 | Output | 0-20mA/4-20mA/0-5V |
10 | Power | 24VDC,100mA |
11 | Ambient temperature range | 0-70ºC |
12 | With air cooling | 120ºC |
13 | With water cooling | 175ºC |
14 | Storage temperature range | -20-70ºC |
15 | Dimensions | L:max185mm; Φ58mm |
16 | Vibration | GB/T2423.8-1995 |